| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | |
| Model Number : | NBN40-L2-A2-V1 |
| Certification : | - |
| Price : | USD300/PC |
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability : | 100 |
| Delivery Time : | 3-5DAYS |
| MOQ : | 1set |
Equipment protection level Gc (nA) Certificate PF 15CERT3754 X CE
marking ATEX marking ¬ II 3G Ex nA IIC T6 Gc The Ex-related marking
can also be printed on the enclosed label. Standards EN
60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection
category "n" Use is restricted to the following stated conditions
Special conditions Maximum operating current IL The maximum
permissible load current must be restricted to the values given in
the following list. High load currents and load short-circuits are
not permitted. Maximum operating voltage UBmax The maximum
permissible operating voltage UB max is restricted to the values in
the following list. Tolerances are not permissible. Maximum
permissible ambient temperature TUmax dependant of the load current
IL and the max. operating voltage UBmax Information can be taken
from the following list. at UBmax=30 V, IL=200 mA 48 °C (118.4 °F)
at UBmax=30 V, IL=100 mA 50 °C (122 °F) at UBmax=30 V, IL=50 mA 51
°C (123.8 °F) at UBmax=30 V, IL=25 mA 52 °C (125.6 °F) Equipment
protection level Dc CE marking ATEX marking ¬ II 3D IP69K T 107 °C
(224.6 °F) X The Ex-significant identification is on the enclosed
adhesive label Standards EN 50281-1-1 Protection via housing Use is
restricted to the following stated conditions Special conditions
Maximum heating (Temperature rise) dependant of the load current IL
and the max. operating voltage UBmax Information can be taken from
the following list. The maximum surface temperature at maximum
ambient temperature is given in the Ex identification of the
apparatus. at UBmax=30 V, IL=200 mA 22 K at UBmax=30 V, IL=100 mA
19 K at UBmax=30 V, IL=50 mA 18 K at UBmax=30 V, IL=25 mA 17 K
Equipment protection level Dc (tc) CE marking ATEX marking ¬ II 3D
Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on
the enclosed label. 1 L+ L4 2 3 1 3 2 4 1 BN 2 WH 3 BU 4 BK Wire
colors in accordance with EN 60947-5-2 (brown) (white) (blue)
(black) Group Germany: +49 621 776 4411 Refer to “General Notes
Relating to Product Information”. USA: +1 330 486 0001 Singapore:
+65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com
fa-info@sg.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com Inductive
sensor NBN40-L2-A2-V1-3G-3D 3 Release date: 2018-11-13 10:42 Date
of issue: 2018-11-13 130625_eng.xml Standards EN
60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure
"tc" Some of the information in this instruction manual is more
specific than the information provided in the datasheet. General
The corresponding datasheets, declarations of conformity, EC-type
examination certificates, certifications, and control drawings,
where applicable (see datasheets), form an integral part of this
document. These documents can be found at www.pepperl-fuchs.com.
The maximum surface temperature of the device was determined
without a layer of dust on the apparatus. Some of the information
in this instruction manual is more specific than the information
provided in the datasheet. Special conditions Maximum permissible
ambient temperature TUmax dependant of the load current IL and the
max. operating voltage UBmax Information can be taken from the
following list. at UBmax=30 V, IL=200 mA 48 °C (118.4 °F) at
UBmax=30 V, IL=100 mA 50 °C (122 °F) at UBmax=30 V, IL=50 mA 51 °C
(123.8 °F) at UBmax=30 V, IL=25 mA 52 °C (125.6 °F) Equipment
protection level Dc (tD) General The apparatus has to be operated
according to the appropriate data in the data sheet and in this
instruction manual. The maximum surface temperature has been
determined in accordance with method A without a dust layer on the
equipment. The data stated in the data sheet are restricted by this
operating instruction! The special conditions must be adhered to!
Special conditions Maximum permissible ambient temperature TUmax
dependant of the load current IL and the max. operating voltage
UBmax Information can be taken from the following list. at UBmax=30
V, IL=200 mA 48 °C (118.4 °F) at UBmax=30 V, IL=100 mA 50 °C (122
°F) at UBmax=30 V, IL=50 mA 51 °C (123.8 °F) at UBmax=30 V, IL=25
mA 52 °C (125.6 °F

|