Sign In | Join Free | My burrillandco.com
Home > High Accuracy Flow Meter >

Fluke 725S Multifunction Process Calibrator Brand New In Stock

    Buy cheap Fluke 725S Multifunction Process Calibrator Brand New In Stock from wholesalers
     
    Buy cheap Fluke 725S Multifunction Process Calibrator Brand New In Stock from wholesalers
    • Buy cheap Fluke 725S Multifunction Process Calibrator Brand New In Stock from wholesalers
    • Buy cheap Fluke 725S Multifunction Process Calibrator Brand New In Stock from wholesalers
    • Buy cheap Fluke 725S Multifunction Process Calibrator Brand New In Stock from wholesalers
    • Buy cheap Fluke 725S Multifunction Process Calibrator Brand New In Stock from wholesalers
    • Buy cheap Fluke 725S Multifunction Process Calibrator Brand New In Stock from wholesalers

    Fluke 725S Multifunction Process Calibrator Brand New In Stock

    Ask Lasest Price
    Brand Name : FLUKE
    Model Number : Fluke 725S
    Certification : CE
    Price : 2140usd/pc
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 500pcs/month
    Delivery Time : 2-3days
    • Product Details
    • Company Profile

    Fluke 725S Multifunction Process Calibrator Brand New In Stock

    FLUKE process calibrator Fluke-725 /APAC/EMEA 725/CN 725S/CN 726/CN

    Specification
    Measurement Accuracy
    Voltage DC
    30 V: 0.02% 2 counts (upper display)
    30 V: 0.02% 2 counts (lower display)
    100 mV: 0.02% 2 counts
    -10 to 75 mV: 0.025% 1 count (via TC connector)
    Current DC
    24 mA: 0.02% 2 counts
    Resistance
    0 to 400 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
    401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
    1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
    Frequency
    2 to 1000 CPM: 0.05% 1 count
    1 to 1100 Hz: 0.05% 1 count
    1 to 10 kHz: 0.05% 1 count
    Sensitivity: 1 V peak-to-peak-minimum
    Pressure
    Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options
    and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
    Source Accuracy
    Voltage DC
    100 mV: 0.02% 2 counts
    10 V: 0.02% 2 counts
    -10 to 75 mV: 0.025% 1 count (via TC connector)
    Current DC
    24 mA (source): 0.02% 2 counts
    24 mA (simulate): 0.02% 2 counts
    Resistance
    15 to 400 Ω: 0.15 Ω (excitation current 0.15 to 0.5 mA), 0.1 Ω (excitation current 0.5 to 2 mA)
    401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA)
    1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA)
    Frequency
    2 to 1000 CPM: 0.05%
    1 to 1100 Hz: 0.05%
    1 to 10 kHz: 0.25%
    Waveform: 5 V p-p squarewave, -0.1 V offset
    RTDs and Thermocouples
    Measure Accuracy
    NI-120: 0.2°C
    PT-100 (385): 0.33°C
    PT-100 (393): 0.3°C
    PT-100 (JIS): 0.3°C
    PT-200 (385): 0.2°C
    PT-500 (385): 0.3°C
    PT-1000 (385): 0.2°C
    Resolution: 0.1°C
    J: 0.7°C
    K: 0.8°C
    T: 0.8°C
    E: 0.7°C
    R: 1.8°C
    S: 1.5°C
    B: 1.4°C
    L: 0.7°C
    U: 0.75°C
    N: 0.9°C
    Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
    XK: 0.6°C
    BP: 1.2°C
    Source Accuracy
    NI-120: 0.2°C
    PT-100 (385): 0.33°C
    PT-100 (393): 0.3°C
    PT-100 (JIS): 0.3°C
    PT-200 (385): 0.2°C
    PT-500 (385): 0.3°C
    PT-1000 (385): 0.2°C
    Resolution: 0.1°C
    Accuracy stated for 4-wire measurement
    J: 0.7°C
    K: 0.8°C
    T: 0.8°C
    E: 0.7°C
    R: 1.4°C
    S: 1.5°C
    B: 1.4°C
    L: 0.7°C
    U: 0.75°C
    N: 0.9°C
    Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
    XK: 0.6°C
    BP: 1.2°C
    Functions
    Ramp
    Source functions: Voltage, current, resistance, frequency, temperature
    Ramps: Slow ramp, fast ramp, 25% step-ramp
    Loop Power
    Voltage: 24 V
    Accuracy: 10%
    Maximum current: 22 mA, short circuit protected
    Step
    Source functions: Voltage, current, resistance, frequency, temperature
    Steps: 25% of range, 100% of range
    General Specifications
    Environmental
    Operating temperature: 14 to 131°F (-10 to 55°C)
    Storage temperature: -4 to 159.8°F (-20 to 71°C)
    Operating altitude: 9842.52' (3000 m)
    Agency Approvals
    EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
    Battery
    Type: 4 x AA alkaline batteries
    Replacement: Separate battery compartment, accessible without breaking calibration seal
    Side Port Connections
    Pressure module connector, also used for remote real-time programming
    Dimensions
    5.1 x 9.3 x 2.4" (130 x 236 x 61 mm)
    Weight
    1.43 lbs (0.65 kg)