    Brand Name : IFM
    Model Number : PN2571
    Certification : CE
    Price : USD$370
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Delivery Time : 4-6weeks
    • Product Details
    • Company Profile

    IFM Pressure Sensor With Display PN2571 PN-250-SEG14-MFRKG/US/ /V

    Product characteristics
    Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
    Measuring range
    0...250 bar 0...3625 psi 0...25 MPa
    Process connection threaded connection G 1/4 external thread (DIN EN ISO 1179-2); Internal thread:M5
    Application
    System gold-plated contacts
    Measuring element metallic thin film cell
    Application for industrial applications
    Media liquids and gases
    Medium temperature [°C] -25...80
    Min. bursting pressure
    1200 bar 17400 psi 120 MPa
    Pressure rating
    500 bar 7250 psi 50 MPa
    Vacuum resistance [mbar] -1000
    Type of pressure relative pressure
    Electrical data
    Operating voltage [V] 18...30 DC; (to SELV/PELV)
    Current consumption [mA] < 35
    Min. insulation resistance [MΩ] 100; (500 V DC)
    Protection class III
    Reverse polarity protection yes
    Power-on delay time [s] 0.3
    Integrated watchdog yes
    Inputs / outputs
    Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
    Outputs
    Total number of outputs 2
    Output signal switching signal; analog signal; IO-Link; (configurable)
    Electrical design PNP/NPN
    Number of digital outputs 2
    Output function normally open / closed; (configurable)
    Max. voltage drop switching output DC [V] 2
    Permanent current rating of switching output DC [mA] 250
    Switching frequency DC [Hz] < 500
    Number of analog outputs 1
    Analog current output [mA] 4...20; (scalable 1:5)
    Max. load [Ω] 500
    Analog voltage output [V] 0...10; (scalable 1:5)
    Min. load resistance [Ω] 2000
    Short-circuit protection yes
    Type of short-circuit protection yes (non-latching)
    Overload protection yes
    Measuring/setting range
    Measuring range
    0...250 bar 0...3625 psi 0...25 MPa
    Analog start point
    0...200 bar 0...2900 psi 0...20 MPa
    Analog end point
    50...250 bar 725...3625 psi 5...25 MPa
    Factory setting / CMPT = 2
    Set point SP
    1.5...250 bar 25...3625 psi 0.15...25 MPa
    Reset point rP
    0.5...249 bar 10...3610 psi 0.05...24.9 MPa
    Min. difference between SP and rP
    1.5 bar 15 psi 0.15 MPa
    In steps of
    0.5 bar 5 psi 0.05 MPa
    Status_B High Resolution / CMPT = 3
    Set point SP
    1.6...250 bar 23...3626 psi 0.16...25 MPa
    Reset point rP
    0.5...249 bar 8...3611 psi 0.05...24.9 MPa
    Min. difference between SP and rP
    1.1 bar 15 psi 0.11 MPa
    In steps of
    0.1 bar 1 psi 0.01 MPa
    Accuracy / deviations
    Switch point accuracy [% of the span] < ± 0,4; (Turn down 1:1)
    Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
    Characteristics deviation [% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
    Hysteresis deviation [% of the span] < ± 0,1; (Turn down 1:1)
    Long-term stability [% of the span] < ± 0,05; (Turn down 1:1; per 6 months)
    Temperature coefficient zero point [% of the span / 10 K] 0,2; (-25...80 °C)
    Temperature coefficient span [% of the span / 10 K] 0,2; (-25...80 °C)
    Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
    Reaction times
    Response time [ms] < 1.5
    Delay time programmable dS, dr [s] 0...50
    Damping process value dAP [s] 0...4
    Damping for the analog output dAA [s] 0...4
    Max. response time analog output [ms] 3
    Software / programming
    Parameter setting options hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
    Interfaces
    Communication interface IO-Link
    Transmission type COM2 (38,4 kBaud)
    IO-Link revision 1.1
    SDCI standard IEC 61131-9
    SIO mode yes
    Required master port class A; (when pin 2 not connected: B)
    Supported DeviceIDs
    Type of operation DeviceID
    Factory setting / CMPT = 2 460
    Status_B High Resolution / CMPT = 3 639
    Note
    For further information please see the IODD PDF file at "Downloads"
    Factory setting / CMPT = 2
    Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
    Min. process cycle time [ms] 2.3
    IO-Link resolution pressure [bar] 0.1
    IO-Link process data (cyclical)
    Function bit length
    pressure 14
    binary switching information 2
    IO-Link functions (acyclical) application specific tag
    Status_B High Resolution / CMPT = 3
    Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
    Min. process cycle time [ms] 3
    IO-Link resolution pressure [bar] 0.1
    IO-Link process data (cyclical)
    Function bit length
    pressure 16
    device status 4
    binary switching information 2
    IO-Link functions (acyclical) application specific tag
    Operating conditions
    Ambient temperature [°C] -25...80
    Storage temperature [°C] -40...100
    Protection IP 65; IP 67
    Tests / approvals
    EMC
    DIN EN 61000-6-2
    DIN EN 61000-6-3
    Shock resistance
    DIN EN 60068-2-27 50 g (11 ms)
    Vibration resistance
    DIN EN 60068-2-6 20 g (10...2000 Hz)
    MTTF [years] 129
    UL approval
    UL approval number J014
    Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
    Mechanical data
    Weight [g] 261.5
    Material stainless steel (630/1.4542/17-4 PH); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
    Materials (wetted parts) stainless steel (630/1.4542/17-4 PH)
    Min. pressure cycles 100 million
    Tightening torque [Nm] 25...35; (recommended tightening torque; Depends on lubrication, seal and pressure rating)
    Process connection threaded connection G 1/4 external thread (DIN EN ISO 1179-2); Internal thread:M5
    Process connection sealing FKM (DIN EN ISO 1179-2)
    Restrictor element integrated no (can be retrofitted)
    Displays / operating elements
    Display
    Display unit 3 x LED, green (bar, psi, MPa)
    Switching status 2 x LED, yellow
    Measured values alphanumeric display, red/green 4-digit