Detailed technical data Mechanics/electronics Supply voltage Vs DC
9 V ... 30 V 1) 2) Power consumption ≤ 2.4 W 3) Initialization time
< 300 ms Design Cylindrical Housing material Metal
(nickel-plated brass, PBT, ultrasonic transducer: polyurethane
foam, glass epoxy resin) Thread size M30 x 1.5 Connection type Male
connector, M12, 5-pin Indication LED display, 2 x LED Weight 210 g
Sending axis Straight Dimensions (W x H x D) 47.5 mm x 47.5 mm x
102 mm Enclosure rating IP65 / IP67 Protection class III 1) Limit
values, reverse-polarity protected Operation in short-circuit
protected network: max. 8 A, class 2. 2) 15 V ... 30 V when using
the analog voltage output. 3) Without load. Safety-related
parameters MTTFD 101 years DCavg 0% Performance Operating range,
limiting range 350 mm ... 3,400 mm, 5,000 mm Target Natural objects
1) In relation to the current measured value, minimum value ≥
resolution. 2) Referring to current measurement value. 3)
Temperature compensation can be switched off, without temperature
compensation: 0.17 % / K. 4) Subsequent smoothing of the analog
output, depending on the application, may increase the response
time by up to 200 %. 2 ULTRASONIC DISTANCE SENSORS | SICK Product
data sheet | 2024-06-27 07:49:40 Subject to change without notice
UM30-214118 | UM30 ULTRASONIC DISTANCE SENSORS Resolution ≥ 0.18 mm
Repeatability ± 0.15 % 1) Accuracy ± 1 % 2) 3) Temperature
compensation ✔ Response time 180 ms 4) Switching frequency 4 Hz
Output time 43 ms Ultrasonic frequency (typical) 120 kHz Detection
area (typical) See diagrams Additional function Adjustable
operating modes: Switching point (DtO) / Switching
window/Background (ObSB) Teach-in of digital output Set levels of
digital outputs Invertable digital output Set on delay digital
output Teach-in of analog output Scaling of analog outputs
Invertable analog output Automatic selection of analog current or
voltage output Synchronization of up to 50 sensors Multiplexing: no
cross talk of up to 50 sensors Adjustable measurement filters:
Measured value filters/Filter strength/Foreground
suppression/Detection area/Sensitivity and sound beam Display (can
be deactivated) Reset to factory default 1) In relation to the
current measured value, minimum value ≥ resolution. 2) Referring to
current measurement value. 3) Temperature compensation can be
switched off, without temperature compensation: 0.17 % / K. 4)
Subsequent smoothing of the analog output, depending on the
application, may increase the response time by up to 200 %.
Interfaces Digital output Number 1 1) Type PNP Maximum output
current IA ≤ 200 mA Analog output Number 1 Type Current output /
voltage output Function Automatic selection of analog current or
voltage output dependent on load Current 4 mA ... 20 mA, ≤ 500 Ω 2)
Voltage 0 V ... 10 V, ≥ 100,000 Ω Resolution 12 bit Multifunctional
input (MF) 1 x MF Hysteresis 50 mm 1) PNP: HIGH = VS - (< 2 V) /
LOW = 0 V. 2) For 4 mA ... 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.
Ambient data Ambient temperature, operation –25 °C ... +70 °C
Ambient temperature, storage –40 °C ... +85 °C 2024-06-27 07:49:40
| Product data sheet Subject to change without notice ULTRASONIC
DISTANCE SENSORS | SICK 3 A B C D E F H I J K L M N O P Q R S T
UM30-214118 | UM30 ULTRASONIC DISTANCE SENSORS Classifications
ECLASS 5.0 27270804 ECLASS 5.1.4 27270804 ECLASS 6.0 27270804
ECLASS 6.2 27270804 ECLASS 7.0 27270804 ECLASS 8.0 27270804 ECLASS
8.1 27270804 ECLASS 9.0 27270804 ECLASS 10.0 27270804 ECLASS 11.0
27270804 ECLASS 12.0 27272806 ETIM 5.0 EC001846 ETIM 6.0 EC001846
ETIM 7.0 EC001846 ETIM 8.0 EC001846 UNSPSC 16.0901 41111960
Dimensional drawing (Dimensions in mm (inch)) UM30-214 3 3 2 102
(4.02) 69 (2.72) 33 (1.30) 19.5 (0.77) Ø 47.5 (1.87) M30 x 1.5 5
(0.20) 5 (0.20) 1 11 (0.43) M12 x 1 ① Connection ② Display ③
Mounting nuts, SW 36 mm Connection type 1 2 4 3 5 4 ULTRASONIC
DISTANCE SENSORS | SICK Product data sheet | 2024-06-27 07:49:40
Subject to change without notice UM30-214118 | UM30 ULTRASONIC
DISTANCE SENSORS Connection diagram UM30-21x118 Connector M12,
5-pin L+ Q/¯Q 1 4 brn blk QA wht 2 3 M blu gra 5 Sync/Multi1 ①
Synchronization and multiplex mode, Connect+ communication
Adjustment possible 2 4 4 5 5 T1 D1 D2 T2 ② Display ④ Control
elements ⑤ Status indicators 2024-06-27 07:49:40 | Product data
sheet Subject to change without notice ULTRASONIC DISTANCE SENSORS
| SICK 5 A B C D E F H I J K L M N O P Q R S T UM30-214118 | UM30
ULTRASONIC DISTANCE SENSORS Detection area 1,600 (63.00) 2,400
(94.49) 2,400 (94.49) 1,600 (63.00) 800 (31.50) 800 (31.50) 0
Detection area in mm (inch) 3 4 5 2 0 800 (31.50) 2,400 (94.49)
1,600 (63.00) 3,200 (125.98) 4,000 (157.48) 5,600 (220.47) 4,800
(188.98) Detection area in mm (inch) 1 ① Detection range dependent
on reflection properties, size, and alignment of the object ②
Limiting range ③ Operating range ④ Example object: aligned plate
500 mm x 500 mm




Switching frequency | 4Hz |
Output time | 43 ms |
Ultrasonic frequency (typical) | 120 kHz |